Maintenance and Handling of Automotive Relays

Nov 12, 2026

Leave a message

hozest
hozest
We focus on industry research and real-time market analysis. We curate practical and professional information content to keep you informed of the latest industry trends.

Soldering Process
1. Flux
Non-sealed PCB-type relays are highly susceptible to flux contamination. It is recommended to use flux-resistant or sealed relays to prevent flux vapors from entering through the terminals or the gaps between the base and the housing. For flux-resistant relays, preheating and drying (100°C for 1 minute) can further prevent flux intrusion.

 

2. Soldering Process
Exercise caution during flux application or automatic soldering to avoid compromising relay performance. Flux-resistant or sealed relays are suitable for dip soldering or wave soldering processes; however, maximum soldering temperatures and durations must be controlled according to the specific relay model.

 

(1). Wave Soldering: The recommended soldering temperature is 240°C–260°C for approximately 5 seconds, with an optimal temperature of 250°C. For other temperature and time combinations (e.g., shortening immersion time when using higher solder temperatures), please contact our technical support team or verify the soldering quality.

 

(2). Manual Soldering: Recommended soldering temperature is 300°C–350°C, with a soldering time of less than 2 seconds.

 

(3). Cooling: Heat generated during the soldering process can be mitigated by a cooling step at the end of the procedure. Avoid sudden temperature changes, and specifically, prevent thermal shock to the relay.

 

Cleaning Process
Use no-clean flux whenever possible and avoid immersing the entire relay in cleaning agents to prevent fluid ingress and subsequent failure. Ultrasonic cleaning is prohibited, as ultrasonic energy can cause contact cold welding, breakage of enameled wires, and other structural damage. Immediately after cleaning and drying, apply forced air cooling to bring the relay back to room temperature.

 

Applying Protective Coating:
To ensure moisture resistance and high insulation for the circuit board, a protective coating is sometimes required. A soft, silicone-free sealant should be selected. The application process must prevent the relay from developing negative pressure that could draw the sealant inside.

 

Inspection and Repair Methods
(1) Simple method for assessing relay performance:
Turn on the ignition switch and listen (using your ear or a stethoscope) for the clicking sound of the control relay engaging, or feel for vibrations with your hand. If present, the relay is generally functioning correctly, and any failure of the associated electrical component is due to other causes; otherwise, the relay is malfunctioning. You can also test the relay by unplugging it. For example, if the A/C compressor fails to operate, start the engine, turn on the blower and A/C switches, and then unplug the A/C compressor relay connector to diagnose the issue. If you hear the relay actuate, and the engine speed drops noticeably when the relay is unplugged and rises again when plugged back in, the A/C compressor relay and its control circuit are functioning normally. Regarding relay location: relays and fuses marked with dash-dot lines on the circuit schematic are generally located within the central power distribution box.


(2) Common relay faults: Common failure modes include burnt-out coils, internal short circuits (due to insulation aging), contact ablation (pitting/burning), thermal degradation, and inability to adjust the initial actuation current.

 

① Burnt-out relay coil: To prevent this, remove temperature-sensitive relays and electronic control units during repairs, maintenance, or electric welding if temperatures are likely to exceed 80°C.

 

② Contact ablation: If cleaning fluid leaks onto the relay, it can cause the normally open contacts to rust and stick in the closed position, leading to a fault where the A/C condenser fan runs continuously. Therefore, strictly prevent water from entering the relay.

 

(3) Measures to reduce relay contact resistance
The contact resistance between automotive relay contacts consists primarily of two components: constriction resistance and surface film resistance. Contact resistance is influenced by factors such as the contact configuration, material properties, and surface finish. Therefore, to reduce contact resistance while maintaining constant contact pressure, one can focus on improving the contact interface and the contact materials themselves.

 

Storage environment: Avoid direct sunlight and maintain normal temperature, humidity, and atmospheric pressure (temperature: 10°C–35°C; humidity: 5–85%). RH: Air pressure: 86–106 kPa. Condensation may form inside the relay in high-temperature, high-humidity environments or when ambient temperatures fluctuate rapidly. Condensation is particularly likely during maritime transport; please pay close attention to transport conditions. Condensation is the phenomenon where water vapor condenses into water droplets when the temperature shifts rapidly-either from high to low or from low to a high-temperature/high-humidity state. Condensation can lead to reduced insulation, coil corrosion or wire breakage, and rusting.

 

Low-temperature freezing: This refers to the phenomenon where moisture adhering to the relay in high-humidity or condensation-prone environments freezes when the temperature drops below the freezing point. Freezing can cause moving parts to stick, delay operation, or result in ice forming between contacts, leading to contact failure.

 

Plastics may become brittle in low-temperature, low-humidity environments.

Long-term storage in environments with high temperatures, high humidity, or the presence of organic or sulfurous gases can lead to the formation of sulfide and oxide films on contact surfaces, resulting in unstable contact and contact failure. Please pay attention to packaging methods to minimize exposure to humidity and organic or sulfurous gases. Relays should be stored and installed in clean environments; use dust covers or sealed relays in dusty conditions. Monitor storage temperatures and avoid prolonged storage periods.

 

Storage and Transport Stress: During transportation, significant impact from dropping the relay may result in functional failure; please inspect the packaging for any signs of damage.

 

Relays are packaged in long tubes; when handling small quantities, the lack of a stopper may cause the relays to slide out, potentially affecting their appearance and performance-please exercise special care in this regard.
 