Automotive control relays must withstand vibration, high and low temperatures, humidity, and corrosive environments. Technical requirements include electromagnetic compatibility, flame retardancy, and fast response. Product structures include three-pin, four-pin, and five-pin types. Circuit switching is achieved by energizing an alloy contact point through a magnetic field coil. For example, a headlight relay controls the headlights via a combination switch's ON/OFF position.
1. Installation Direction: Installing the relay in the same direction as its shock resistance will maximize its performance. It is recommended that the impact direction be perpendicular to the movement direction of the contacts and armature. This effectively improves the vibration and shock resistance of normally closed contacts in the unenergized state. During installation, ensure the relay contact axis is parallel to the ground to prevent contact debris and carbon deposits from falling onto the contact surface, improving contact reliability. For multiple relays, avoid placing the low-load contact below the high-load contact.
2. Close-Range Installation: Installing multiple relays close together can cause abnormal heating. A 2mm spacing is generally recommended. Close-range installation of polarized or magnetically latched relays can affect the operating voltage.
3. For relays mounted in a housing, do not remove the housing before installation. To prevent loosening, damage, or deformation, please use spring washers. Tightening torque should be within the range of 0.5–70 N·m.
4. The recommended insertion strength for plug-in relays is 40–70 N.
5. Products meeting the same load requirements have different external dimensions. Depending on the allowable installation space, choose a product with a lower height or smaller installation area.
6. Automotive relays can be installed using PCB board mounting, ISO socket mounting, ISO 280 socket mounting, and housing-fixed or clip-on mounting methods. For small relays that are not frequently replaced, PCB board mounting is generally preferred; for relays that are frequently replaced, socket mounting is preferred. For relays with a main circuit current exceeding 20A, quick-connect socket mounting is generally preferred to prevent high current from passing through the circuit board and causing overheating and damage (except for short-term operating relays). For large relays, housing mounting can be used to prevent damage to the mounting feet under impact and vibration conditions.