The following are the causes of automotive relay failure:
1. Incorrect auxiliary contact position: After repeated tripping, the mechanical parts of the switch may shift or wear, causing the auxiliary contact to deviate from its correct position. When the protection trips, the auxiliary contact may not open before the output electrical components, relays, and circuit breakers have already returned to their original positions. This means the intermediate electrical components and relay contacts disconnect before the auxiliary contact. This causes the intermediate electrical components and relays to burn out when disconnecting the DC power supply. Therefore, in the event of an accident, although the protection has tripped, the switch itself may not, resulting in an over-trip.
2. Jammed switch tripping mechanism: Due to lack of maintenance, the switch mechanism may become sluggish during operation, with jamming areas preventing normal tripping. This causes the intermediate electrical components and relay coils to remain energized for extended periods, eventually burning out and preventing proper operation.
3. The trip coil core is detached or stuck: Due to repeated normal operation and fault tripping of the switch, the trip coil core set screw becomes loose, causing the trip coil core to detach. When a fault occurs, it cannot trip, causing the intermediate electrical appliances and relays at the outlet to be energized for a long time, which will burn out the electrical appliances, relay coils, or contacts.